ThermTrace® X

SELF-REGULATING PARALLEL HEATING TAPE

Properties of heating tape

• Self-regulating

• 4 power output ranges

• Cut-to-length

• Chemical resistant

• For extremely high temperaure

Technical data

Maximum exposure temperature (unpowered): 250°C

Maximum operating temperature: 165°C

Nominal voltage: 230V

Min. bending radius: 25mm

Min. installation temperature: -60°C

Buswires: nickel plated copper

Applications

The ThermTrace X is an industrial grade self-regulating heating tape for extremly high temperatures. Its application range from freeze protection and temperature maintenance of pipework and vessels in a large number of industrial applications and Ex-areas such as power plants or chemical, petrochemical or oil and gas industry.



Properties of heating tape

Name

 

Power output 

on insulated

metal pipes

at 10°C (W/m)

Maximum permissive
temperature (°C)

Nominal 

Dimension 

15 TTX-2-BOT  15

250

14.0 x 5.5

35 TTX-2-BOT   35  250  14.0 x 5.5 
45 TTX-2-BOT  45  250  14.0 x 5.5
75 TTX-2-BOT   75 250  14.0 x 5.5

Product ordering information:

TTX-2-BOT: Cable with protective braid and fluoropolymer overjacket

Maximum recommended length of heating circuit at 230 VAC using Type-C circuit breakers:

Product 

Reference

Circuit 

Breaker

-10°C

0°C

+10°C

15TTX  10A  118m  122m  128m
15TTX  20A  170m  170m  170m
15TTX  32A  173m  173m 173m 
15TTX  40A  173m  173m  173m
35TTX  10A  47m  51m  53m
35TTX  20A  95m  99m  105m
35TTX 32A  107m 107m 107m
35TTX  40A  108m 108m 108m
45TTX 10A  33m 34m 36m
45TTX 20A  66m 70m 73m
45TTX 32A 96m 98m 99m
45TTX 40A 98m 99m 100m
75TTX 10A  17m 18m 19m
75TTX 20A  33m 36m 38m
75TTX 32A 54m 58m 61m
75TTX 40A 67m 72m 74m

Temperature (°C) / Loading (W/m) diagram