• Self-regulating
• Special designed for use in concrete
• Cut-to-length
• Highly robust
Maximum exposure temperature (unpowered): 100°C
Maximum operating temperature: 85°C
Nominal voltage: 230V
Min. bending radius: 40mm
Min. installation temperature: -30°C
Power output at 0 °C in concrete: 80 W/m
The ThermTrace RampTrace is a construction grade self-regulating heating tape applicable for snow and ice melting of ramps, stairs, walkways and helicopter landing platforms. To ensure a high mechanical load capacity, the ThermTrace RampTrace is especially robust.
Name |
Power output on insulated metal pipes at 10°C (W/m) |
Maximum permissive |
Nominal Dimension |
TTRT-2-BO | 55 |
100 |
17.3 x 9.1 |
Product Reference |
Circuit Breaker |
+10°C |
0°C |
-10°C |
-20°C |
TTRT | 30A | 55m |
46m |
40m |
35m |
TTRT | 50A | 70m | 64m | 55m | 49m |